SAFETY CONSIDERATIONS

CAUTION - MAINS FUSE
TO REDUCE THE RISK OF FIRE REPLACE THE MAINS FUSE ONLY WITH THE SAME TYPE, WHICH MUST BE A CLASS 3, 230 VOLT, TIME DELAY TYPE, RATED AT 50mA WHERE THE MAINS INPUT VOLTAGE SWITCH IS SET TO 230 VOLTS AC. AND 100mA WHERE THE MAINS INPUT VOLTAGE IS 115 VOLTS AC. ALL FUSES MUST COMPLY WITH BS EN 60127-2:1991, SHEET III. THE FUSE BODY SIZE IS 20mm x 5mm.

CAUTION - MAINS CABLE
DO NOT ATTEMPT TO CHANGE OR TAMPER WITH THE SUPPLIED MAINS CABLE.

CAUTION - SERVICING
DO NOT PERFORM ANY SERVICING. REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL.

WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.

top of page

INTRODUCTION
Designed to meet the needs of professional studio and live sound applications, the DRAWMER DL251 dual channel compressor/limiter has many advanced features including the choice of hard-knee or soft-knee characteristics, an automatic attack and release mode, and Dynamic Spectral Enhancement to maintain transient detail during compression conditions.

The DL251 may be used in either balanced or unbalanced systems and each channel is independently switchable between +4dBu and -10dBV operating levels. In addition to the compressor/limiter, each channel also contains an independent, full-wave peak limiter.

Because the compressor section offers a choice of traditional hard-knee, ratio style compression or soft-knee compression, it is equally adept at creative work and unobtrusive level control. The control lay-out follows that of a ratio style unit, but when the soft-knee characteristic is switched in, the transition from unity gain to gain reduction at the selected ratio is progressive and occurs over a nominal 10dB input level range.

Soft-knee compressors are often chosen in applications that call for inconspicuous level control whereas ratio type compressors are generally considered more successful in creative applications or where large amounts of gain reduction are required. By offering both alternatives, the DL251 is capable of outstanding results in a very wide range of studio and live sound situations.

A feature of the DL251 is a highly effective peak limiter which allows the user to set an absolute output level that can never be exceeded. This facility is extremely valuable both in live sound applications, for driver protection, and in digital recording where an absolute maximum recording level exists. Furthermore, when the unit is deliberately driven into limiting, it can be used creatively to produce level 'pumping' effects.

The DL251 also includes the newly developed Dynamic Spectral Enhancement system which is designed to compensate for the loss of transient detail that tends to occur during periods of heavy compression. This system is dynamically related to the degree of gain reduction taking place which means that processing is applied only when needed, and the degree of enhancement is set using just a single rotary control.

top of page

INSTALLATION
The DL251 is designed for standard 19" rack mounting and occupies 1U of rack space. Avoid mounting the unit directly above power amplifiers or power supplies that radiate significant amounts of heat and always connect the mains earth to the unit. Fibre or plastic washers may be used to prevent the front panel becoming marked by the mounting bolts.

AUDIO CONNECTIONS
INPUTS and OUTPUTS: Both the input and output XLRs may be used either balanced or unbalanced, the wiring convention being: pin 1 Ground, pin 2 Hot and pin 3 Cold. The rear panel push buttons should be released (out) for +4dBu operation or depressed (in) for -10dBV operation in order to optimise the internal gain structure of the unit. For use with unbalanced systems, the Cold pin (3) must be grounded at both input and output XLRs.

If earth loop hum problems are encountered, don't disconnect the mains earth but instead, try disconnecting the signal screen on the cables connecting the DL251 to the patchbay. If such measures are necessary, balanced operation is recommended.
S/C INSERT: The side-chain insert point is configured as a stereo jack socket wired tip return, ring send. This point is unbalanced and would normally be connected to a normalised or semi-normalised pair of patchbay contacts.

PEAK / AVERAGE LINKING
A rear panel switch gives a choice of two linking characteristics which only apply when the unit is switched for stereo linked operation: Peak or Average. In Peak mode, the gain control of both channels is derived from the peak level of whichever channel is currently loudest, while in Average mode, the control signal is derived from the average of the two channel levels. Most users have a preference for one or other mode of operation so once this switch is set, it is unlikely to be changed again.

POWER CONNECTION
The unit will have been supplied with a power cable suitable for domestic power outlets in your country. For your own safety it is important that you use this cable. The unit should always be connected to the mains supply earth using this cable.

If for some reason the unit is to be used at a mains input operating voltage which is different to that as supplied, the following procedure must be carried out.
  1. Disconnect the unit from the mains.
  2. Using a number 1 size pozidrive screwdriver, remove the two self-tapping screws holding the voltage selection switch cover plate on the rear panel.
  3. Remove the cover plate and slide the switch fully to its opposite end.
  4. Rotate the cover plate one half turn, (180 ) and refit the two screws.
  5. Replace with a correctly rated fuse for the selected operation voltage.
  6. Re-connect to mains power source.

top of page

CONTROL DESCRIPTION
Both channels of the DL251 are identical and may be used completely independently or linked for stereo operation. In the linked mode, only the left hand channel controls are functional and serve as master controls while both the compressor/limiters, and the peak limiters of the two channels track together.

COMPRESSOR
Threshold: Determines the input level above which gain reduction will be applied and may be set in the range -40 to +20dB. In the 'Soft' mode, the onset of compression is progressive over a nominal range of 10dB, while in 'Hard' mode, gain reduction is applied as soon as the threshold is reached.

Hard/Soft-Knee: This switches between conventional ratio and soft-knee characteristics. A red status LED indicates hard-knee operation with a yellow LED indicating soft-knee operation.

Ratio: Sets the compression ratio in the range 1:1 to infinity:1 allowing the possibility of true hard limiting as well as compression. In soft-knee mode, the ratio increases progressively around the threshold point to a maximum of the value set by the Ratio control.

Gain Reduction Meter: A nine segment LED bargraph meter continuously monitors the gain reduction applied by the compressor/limiter over the range 0 to 30dB.

Attack: Sets the rate at which the compressor will respond to input signals that exceed the threshold level. This may be set in the range 0.5mS to 100mS.

Release: Sets the rate at which the system gain returns to normal after the input signal level has fallen below the threshold. Adjustment ranges from 50mS to 5 Sec.

Auto: When selected, Auto disables the Attack and Release controls and continually optimises the attack and release times to suit the dynamics of the material being processed. In general, this setting will produce the least obtrusive level control on signals with widely varying dynamics such as complete mixes.

S/C Listen: This facility allows the user to listen to the side-chain signal. This is useful if an external processor, such as an equaliser, has been connected via the rear panel insert socket. When this switch is active, the post -insert S/C signal is routed directly to the output of the DL251.

Gain: The output level may be attenuated or amplified by up to 20dB to compensate for level changes caused by compression and limiting. This control comes before the Peak limiter detector and will, as a consequence, influence the limiter action.

Bypass: the DL251 features a 'hard bypass' which directly links the input sockets to the outputs when Bypass is active. The adjacent red LED indicates the Bypass status.

Output Level Meter: a 10-segment LED bargraph level meter monitors the level of the output signal over the range -20dB to +15dB with reference to the selected (-10dBV or +4dBu) operating level.

top of page

DYNAMIC SPECTRAL ENHANCEMENT
Enhance: Signals exceeding the compression threshold are dynamically enhanced to prevent transient detail being compromised when powerful, low frequency sounds occurring at the same time cause the compressor to apply gain reduction. A typical example is a hi-hat sound occurring at the same time as a bass drum beat; as the compressor pulls down the gain in response to the bass drum level, the hi-hat will be reduced in level by a corresponding amount. A switch marked 'On' with a yellow status LED switches the Enhance system in and out of circuit for A/B checking.

The DL251 contains advanced circuitry which dynamically controls the phase and spectral content of the programme material to lift transient detail during times when compression is applied, and the degree of processing is related to the amount of gain reduction taking place. The green LED above the Enhance control shows the degree of enhancement taking place, and turning the control clockwise will increase the amount of processed signal added to the programme material. With the enhance control rotated fully clockwise and dynamic programme material the green LED will apparently be illuminated constantly, but this is not the case, dynamic enhancement will still be occurring, only the peaks are now so close together that the human eye cannot detect the frequency.

The Enhance control comes before the Peak Limiter in the signal side chain, therefore more Enhance can cause more Limiting.

top of page

PEAK LIMITER
Level: This control sets an absolute limit that the output signal may not exceed. This limiter is very fast acting enabling it to control any peaks without audible distortion. If the output signal is so high as to cause the limiter to operate for more than 20mS, the system gain is automatically reduced to bring the signal back within range. The system gain is then returned to normal over a period of approximately one second. The compressor Gain control should be used to ensure that the peak limiter operates only occasionally if the limiter is to be used purely for peak protection. Alternatively, it may be deliberately driven into limiting to produce creative effects.

STEREO
Stereo Link:
This switch configures the channels for processing stereo programme material where the left hand channel's controls act as master for both audio channels. Linking applies to all switch and knob functions without exception including Bypass and S/C Listen. Only the output level meters remain independent.

The same degree of gain reduction is applied to both audio channels to prevent image shifting which would otherwise occur whenever the left and right signal dynamics varied from each other by any significant degree. If the rear panel Link button is set to Peak, then the gain reduction is controlled by the peak level of whichever channel is loudest at any time. In the Average position, the compressor always works from an average of the two channel signals regardless of their relative levels.

The operation of the Stereo Link with the rear panel detection switch set to Peak will be most unpredictable when one channel is operating at +4dB and the other at -10dB. The signal on the channel set to -10dB will most likely control the stereo side chain all of the time.

top of page

SIDE CHAIN INSERT
The stereo 1/4" jack socket offers the option to insert other external signal processing into the control side chain. The jack socket is configured as the Ring contact being signal send and the Tip contact being signal return. The signal at the jack socket is at -6dB (ref +4dB). This level remains constant irrespective of the operating level set by the rear panel switch.

The most common use of this connection is to patch in some equalisation for 'frequency sensitive' compression, normally called de-essing. The standard method is to insert some boost of the obtrusive frequencies so the compressor side chain 'sees' more of these frequencies and applies more compression than would be normally applied. The use of this facility and extensive enhancement could be counter productive, so some moderation is advised.

If the side chain jack socket is permanently wired into a patch bay, it must be connected to a fully normalised pair of sockets. Any poor wire terminations or jack socket closing contacts in the side chain jack wiring will certainly cause some distortion, and may totally prevent compression from happening.

top of page

OPERATION
The unit should be connected in-line with the signal to be processed via suitable insert points. Ensure that the insert send and return level on your console matches the operating level set up using the push-buttons on the rear panel of the DL251. If not, select the appropriate operating level on the DL251.

For mono use, each channel may be considered as being completely independent and set up accordingly. For use with stereo signals such as complete mixes or submixes, the unit should be switched to Stereo Link mode and all setting up done using the left hand channel's controls. The choice of Peak or Average linking is down to user preference and must be selected via the rear-panel switch.

Initial setting up is best accomplished with the peak limiter threshold set to maximum. This allows the compressor/limiter to be set up in isolation. Very generally, the 'hard' ratio setting provides the most positive means of controlling gain and is invariably the preferred choice if the compressor is to be used creatively. Examples include the treatment of individual drum or guitar sounds, or for making rock vocals 'sound' compressed.

The 'Soft' setting, on the other hand, is often most effective in controlling the dynamics of a complex signal where unobtrusive control is required. Typical applications include complete mixes or submixes, vocals where a natural sound is to be maintained, and instruments that need to retain their original character.

The ratio setting depends on how firmly the signal dynamics need controlling; as a rule, higher ratios provide a higher degree of control but also tend to be more audible in operation when high levels of gain reduction are required, especially when the 'Hard' setting is selected. The integral soft-knee feature of the DL251 renders these effects far less pronounced, but this factor should still be taken into consideration when setting up. In general, when 'Soft' is selected, a higher compression ratio may be used without compromising the sound quality.

If the Attack and Release controls are switched to Auto, setting up is simply a matter of adjusting the Threshold control until the desired amount of gain reduction occurs. This is judged partly by ear and partly by observing the gain reduction meter. Typically, a maximum gain reduction of between 8dB and 12dB will be adequate. If more gain reduction appears necessary, it is safer to apply a conservative degree of compression during recording and then further compression while mixing.

Compression will increase the subjective level of tape and other background noises during pauses and quiet passages because the maximum gain condition occurs when the input signal is at its lowest level. Consequently, the input signal should always be as noise-free as possible and the amount of gain reduction applied should never be more than is necessary. If the compressor is set up so that the gain reduction meter is, for example, reading 10dB during signal peaks, the signal-to-noise ratio during quiet passages or pauses will be degraded by 10dB.

The Auto control may be switched off if it is desired to set the attack and release times manually. The longer the attack time, the longer the compressor takes to respond to increases in signal level and a slow attack time is often used to accentuate the beginning of percussive or plucked sounds such as drums, basses and guitars. A fast attack time will bring the input signal under control very quickly. Effects created by lengthening the attack time are more pronounced when the DL251 is set for 'Hard' compression.

In normal use, the release time should be set short enough so that the system gain has returned to normal before the next peak occurs and, in general, it should be set as short as possible before audible gain 'pumping' occurs.

Set the Gain control to give the required output level using the level meter to guide you. Avoid running at very high output levels as this reduces the available amount of signal headroom and could lead to distortion in extreme cases. Once the gain is correct, set the Peak limiter Level control so that the limiter LED only lights briefly on extreme signal peaks. Alternatively, set the Peak limiter Level to the desired value and then adjust the compressor Gain control to ensure minimum limiter activity.

Compression is often accused of dulling the sound being processed, and a little explanation is needed to understand exactly why that is. What happens is that bass sounds, which contain most of the energy in a typical piece of music, cause the compressor to operate, and so any quieter, high frequency sounds occurring at the same time as the bass sound will also be turned down in level. That's why the cymbals and hi-hats in a heavily compressed drum track seem to dip in level whenever a loud bass drum or snare drum beat occurs.

A partial solution is either to use less compression or increase the attack time to allow the leading edge of the brighter sounds to pass through the compressor before the gain reduction occurs. However, the DL251's Dynamic Spectral Enhancement feature is designed to prevent the above side-effect by applying dynamic boost to a selective part of the audio spectrum during the period of compression. Once the compressor has been set up normally, the Enhance control setting may be increased as desired.

The Peak limiter has no bypass control, but turning the Level control fully clockwise will prevent any unwanted limiter action. Conversely, by selecting a compression ratio of 1:1, the limiter may be used on its own.

top of page

CREATIVE APPLICATIONS
The Enhance control may also be used to create special effects by deliberately over-enhancing the transient detail of a signal. Because the Dynamic Spectral Enhancement system is dynamically related to the amount of gain reduction taking place, it is necessary to set up the compressor accordingly. Selecting a long decay time will help maintain a high average level of gain reduction while not interfering with the short-term dynamic detail of the signal.

Typical examples include adding extra brightness to steel-strung acoustic guitars or electromechanical pianos, but the applications are limitless and may be extended to cover all manner of synthesised and sampled sounds, percussion and vocals. On a cautionary note, when treating vocals, check that the process is not over-emphasising any natural sibilance inherent in the sound.

PEAK LINKING
When the DL251 is being used to compress actors' voices along with a stereo soundtrack, it would be common practice to have a fully-stereo low-level music 'pad' and the louder speech parts panned appropriately to match the visual image. In this configuration Peak type Linking should deal with the programme correctly, without any stereo sound shifting.

SIDE CHAIN INSERT
By patching an equaliser into the side-chain insert point, the compressor can be made to operate in a frequency-selective manner. The S/C Listen switch enables the user to monitor the effect of the equaliser and, because of the compressor action, signals that are most predominant in the equalised sound will cause the greatest degree of gain reduction. This is commonly exploited in de-essing where vocal sibilance in the range 5kHz to 10kHz can cause problems. By adding, say, a 10dB boost centered at 7kHz, the sibilant sounds fed to the side-chain will be emphasised and, as a consequence, greater gain reduction will be implemented whenever any sibilance occurs.

top of page

DL251 TECHNICAL SPECIFICATIONS

INPUT IMPEDANCE 22K Ohm
MAXIMUM INPUT LEVEL +21dBu (+17dB ref. +4dBu)
OUTPUT IMPEDANCE 50 Ohm
MAXIMUM OUTPUT LEVEL +20dBu
BANDWIDTH <12Hz to 25KHz -1dB
CROSSTALK   @10kHz Better than -80dB
                       @20kHz Better than -70dB

NOISE AT UNITY GAIN reference +4dBu
               Wideband         22Hz - 22KHz        CCIR ARM         IEC A       Q-Pk CCIR
AV              -88dB                 -94dB                  -95dB             -98dB          -84dB
RMS           -86dB                 -92dB                  -93dB             -96dB              -

DISTORTION (No Compression and Enhance Off)
                                              100Hz        1KHz         10KHz
Unity Gain, +4dBu Input          < 0.09%    < 0.03%       < 0.08%
+14dBu Input, 10dB G.R.        < 0.15%    < 0.15%       < 0.15%

POWER REQUIREMENTS 115Volt or 230Volt at 50-60Hz, 10 Watts
FUSE RATING 50mA for 230Volt, 100mA for 115Volt
CONFORMING TO BS EN 60127-2:1991 SHEETIII
FUSE TYPE 20mm x 5mm, Class 3 Slo-Blo, 250Volt working
CASE SIZE 482mm (w) x 44mm (h) x 200mm (d)
WEIGHT (incl packaging) 3.4 Kgs