Global Parameters
Air temperature: 22°C
Air pressure: 101325 Pa X Axis: Frequency Range: 20Hz - 20000Hz Scale: logarithmic Resolution: high Angle of incidence: 0° Porous model: Komatsu (2008) Helmholtz model: Ingard/Allard |
Absorber Parameters
• Absorber 1 (OC703 100mm No Air Gap)
100mm Porous Absorbent, 23600 Pa.s/m2 Rigid backing • Absorber 2 (OC703 50mm 50mm Air Gap) 50mm Porous Absorbent, 23600 Pa.s/m2 50mm Air Rigid backing |
Dotted lines indicate that the model used to estimate absorber properties has been used outside of its applicable range. Results may therefore be less accurate than where a solid line is displayed.