Acoustic Modelling
Porous Absorber Calculator
Helmholtz Absorber Calculator
Multi-layer Absorber Calculator
Username
Password
Forgotten password?
Register
20 50 100 200 500 1000 2000 5000 10000 20000 Frequency (Hz) 0 0.2 0.4 0.6 0.8 1 Absorption Coefficient Sonorock (5cm) Basotect G (5cm)
Absorption
Coefficient
Reflection
Coefficient
Impedance
(real)
Impedance
(imag)
Amend
Parameters
Global Parameters
Air temperature: 22°C
Air pressure: 101325 Pa

X Axis: Frequency
Range: 20Hz - 20000Hz
Scale: logarithmic
Resolution: medium

Angle of incidence: random
Porous model: Delany and Bazley (1970)
Helmholtz model: Ingard/Allard
Absorber Parameters
Absorber 1 (Sonorock (5cm))
100mm Porous Absorbent, 6000 Pa.s/m2
Rigid backing
Absorber 2 (Basotect G (5cm))
100mm Porous Absorbent, 12400 Pa.s/m2
Rigid backing
Dotted lines indicate that the model used to estimate absorber properties has been used outside of its applicable range. Results may therefore be less accurate than where a solid line is displayed.

Impedance plots are not available for random incidence.